Q-ARE 100 - Quick Automated Radionuclide Extraction
The days of staring at columns are behind you…
In the past, the actions required to characterise the radioactivity from environmental and decommissioning samples, relied solely on gravity; in more recent times, vacuum boxes have been employed to increase speed; The LKB-Hidex Q-ARE 100 introduces vastly decreased process times, and complete ‘push play and walk away’ automation to increase efficiency, throughput, and ease of use.
The Q-ARE 100 is the most advanced automatic extraction chromatography system dedicated to radionuclide separation processes. A truly quick and easy-to-use unattended radionuclide extraction system. User friendly, intuitive, and hassle-free.
Automatic
Manual operation or control is not required
Flow rate can be automatically controlled following user’s need or specification.
Ultimately reduces preparation time and man-hours needed.
Compact
Safety oriented compact design with acrylic doors keeps you safe.
With this clean & compact look, your work areas will have gain more space and less clutter.
Convenient
From one sample, up to 5 targeted radionuclides can be extracted.
Compatible with a range of commercially available extraction columns
Specifications:
Pump: THOMAS* Peristaltic pump
No. of Pumps: 8
Speed: 0.4 ~ 300 rpm
Operating flow rate: 0.1~10ml/min.
Motor Stepper: motor, bipolar, stepping angle 1.8°
Material of the hose clip: PVDF
Nominal voltage: 24V/DC
Max. suction height: 8 m H2O
Max. pressure height: 10 m H2O
Max. ambient temperature: 40°C
Media temperature: 50°C (short time 90°C)
Solenoid valve function: DC 24V, CoolCube-R, (Bio-Chem*) applied, Provides Hit and Hold function, Reduces power consumption at holding state
Flow Selection Valves: Bio-Chem* flow selection valve
No. of port: 2, 4, 6-port
Orifice size: 0.062”
Body: PEEK
Diaphragm: PTFE
Internal volume: 2-port: 27/15 (Com. Port / Inlet Port), 4-port: 117/35 (Com. Port / Inlet Port), 6-port: 207/35 (Com. Port / Inlet Port)
Tube/Fitting material: PTFE, PEEK, ETFE
Acceptable Columns: 2~20ml column(PP or glass) compatible with columns of Triskem*& Eichrom*
Target Radionuclides: Am, Cm, Pu, U, Th, Sr, Pb, Po, Ra-226, Ra-228, etc.
Number of Inlet
Solvent delivery: 8
Washing: 8
Number of Outlet
Sample fractionation: 8
Waste: 8
Max. No. of operating columns
No. of reagent port: 12
No. of sample collection: Max. 40
Acceptable sample: 10, 50ml Tube and 20ml collection bottle scintillation Vial
Large volume sample: 8 (more than 50ml) port
Operating Temperature: +4°C to 40°C
Output: USB port:
Operating system(OS): Windows 10
Power: 110-240V AC, 50/60Hz
Dimensions:(WxDxH): 88x56x65cm
Weight: 45kg